WZK Two-Way Diverter Valve: Dual-Channel Isolation for Powders

Created on Today
A two-way diverter is often specified as if it were just a smaller three-way valve. It is not. The WZK has a different job: it gives a powder or granule line two independent shut-off paths in one compact cylindrical body, so one branch can be positively closed while the other keeps running. This guide explains how that mechanism works, where it earns its keep, and how to read the dimensional data before you place an order.

What "Two-Way" Actually Means

A conventional diverter has one inlet and two outlets: it routes material from A to B or A to C. The WZK instead contains two separate flow paths inside one housing. A cylindrical rotor turns through a short arc to open one path and close the other. The result is not simply direction control but positive isolation — the idle branch is physically shut off, not merely left unconnected.
WZK two-way diverter valve with compact cylindrical cast aluminium body
Photo 1 — WZK two-way diverter valve. The round housing has no square corners where product can sit, and the rotor travels a short arc between its two positions. That short stroke keeps switching time low and allows a small pneumatic cylinder to do the work. The valve is intended for installation in pneumatic conveying lines and gravity pipes.

How the Rotor and Seals Work

Inside the body, the rotor carries a passage that lines up with either the straight-through path or the angled path. One pneumatic cylinder drives it between those two positions. What makes the design suitable for pressurized conveying is the sealing arrangement: both seats are pressure-assisted seals mounted in the housing. Conveying pressure itself pushes the seal against the rotor, so tightness improves as system pressure rises.
This is the practical difference from a simple flap. A flap diverter has to rely on the flap lying flat against a seat, and once that edge wears or picks up product the idle leg starts to leak. On the WZK, the pressure in the line is doing part of the sealing work. For the wider comparison of mechanisms, see our guide to the five types of diverter valves.
WZK diverter valve side view showing pneumatic actuator and signal box
Photo 2 — Side view with actuator. The actuator sits close to the body and the signal box can be fitted on the right or the left. We can supply the pneumatic cylinder alone or the complete operating set: 5/2 solenoid valve, air filter regulator, speed controllers and a signal box for open and closed feedback.

Where a Two-Way Diverter Earns Its Keep

Use a WZK when the line must be shut off positively, not just redirected. Typical arrangements include isolating one of two silos during a changeover, serving two process steps from a single conveying line, or letting one section be cleaned or maintained while the rest of the plant keeps running. Cement and lime, alumina and silica sand, PVC and plastic pellets, fertilizer, feed and grain, chemical powders and fly ash are all normal duties.
If your requirement is only to choose between two destinations on a low-pressure gravity drop, a plate or flap design may be the better purchase. We compare those duties on the diverter valve range page, and the VAB flap diverter is the lighter alternative for non-hygiene service. For a complete system view, start with bulk solids handling valves or pneumatic conveying valves.

Sizes, Flanges and Construction

Seven sizes cover DN50 to DN200: WZK50, WZK65, WZK80, WZK100, WZK125, WZK150 and WZK200. Flanges are drilled either to DIN PN10 or to ANSI #150 (ASME 16.5 class 150). The standard housing is cast aluminium with a stainless steel pipe insert in the flow path, designated CR. A reduced-bore version, CD, is available where a higher velocity is wanted or where the valve must match a smaller pipeline.
WZK two-way diverter valve with DIN PN10 and ANSI flange options
Photo 3 — Flanged ports. Because both flange standards are offered on the same body length, a WZK can often be swapped into an existing line without reworking the pipework. Confirm which drilling the site uses before ordering — the two patterns are not interchangeable.
Type
ØX
ØY
ØD
ØZ
ANSI ØY
ANSI ØD
A
B
C
E
F
G
H
J
K
L
M
N
O
T
R*
WZK 50
50
125
4ר18
165
120.6
4ר19
90
270
35
175
M10×20
205
620
12.5
170
270
170
110
M10
16
33.5
WZK 65
65
145
4ר18
185
139.7
4ר19
85
275
42.5
205
M10×20
215
680
12.5
180
290
190
115
M10
16
36.7
WZK 80
80
160
8ר18
200
152.4
8ר19
110
325
48.5
240
M10×20
255
770
15
195
325
205
125
M10
18
36.6
WZK 100
100
180
8ר18
228
190.5
8ר19
90
370
57.5
260
M10×20
270
815
15
225
360
230
130
M10
18
35
WZK 125
125
210
8ר18
250
215.9
8ר22.2
115
450
70
320
M12×20
335
990
17.5
265
430
255
150
M12
20
35.5
WZK 150
150
240
8ר22
285
241.3
8ר22.2
120
510
82.5
370
M12×20
375
1060
20
295
480
290
165
M12
20
35.8
WZK 200
200
295
8ר22
343
298.4
8ר22.2
135
710
115
495
M12×20
500
1295
25
380
620
350
200
M12
25
34.8
All dimensions in mm. Flanges drilled to DIN PN10 or ASME 16.5 class 150. The drawing shown in the catalogue is for a right-hand signal box; a left-hand version is available.

Working Limits You Must Respect

Maximum system and differential pressure is 5 barg (73 psi), and the operating temperature range is −20 °C to +100 °C. The media are powders, granules, pellets and other free-flowing bulk solids. Abrasive products can be handled with the wear-protected option. Exceeding the pressure rating does not just shorten seal life — it changes the force balance the pressure-assisted seals depend on.
Every valve position costs pressure. If the line is already tight on air, read our note on pressure drop and air cost before adding another diverter. Choosing a smoother route often saves more than changing the valve body.
Complete WZK two-way diverter valve assembly with pneumatic cylinder
Photo 4 — Complete assembly. The wear-protected rotor, seal compounds matched to the product and temperature, a quick-cleaning design, and accessories for Ex zones are all available as options. Tell us the zone and the dust or gas class at enquiry stage.

WZK or a Conventional Diverter?

Choose a WZK when the idle leg must be sealed against line pressure, when one branch is regularly taken out of service, or when the available space will not accept a larger box-type body. Choose a plate, plug or ball diverter when the requirement is simply to route a stream between two outlets. The WZK product page carries the specification, and the five-type comparison sets out the trade-offs between all the designs we build.

Ordering Checklist

To quote a WZK we need five things: the bore (WZK50 to WZK200), the flange standard (DIN PN10 or ANSI #150), the media and its temperature, the conveying pressure, and whether the complete actuator set is required. Add the switching frequency and any Ex requirement if they apply. Send the details to zjxnjx@126.com and we will return the drawing, the price and the delivery time.
WZK two-way diverter valve for powders and granular bulk solids
Photo 5 — WZK ready for dispatch. The valve body carries a 12-month warranty. Rotor, seats and seals are wear parts and are excluded, and we state that plainly on every quotation so there is no surprise at service time.
Need help selecting the right diverter for your line? Write to zjxnjx@126.com with your media, bore and pressure — we will reply with a recommendation and a drawing.
Contact